DUAL SOURCE METER EM9024
 
Features
 
  • True RMS measurement
  • 3 or 2 Element measurement
  • Confirms IS14697 for Accuracy Class 1
  • Programmable PT/CT Primary
  • Direct reading without multiplication factor
  • Low PT, CT burden. (Less than 0.2 VA)
  • Energy storage in EERAM
  • Auto scaling from Kilo to Mega
  • Reverse indication for proper connection
  • Measures 4 quadrant power and records import energy
  • Digital Calibration by software
  • Quick & easy to install
  • Replace 2 Nos. energy meter in the panel
  • Only one potential free contact is required to differentiate EB/DG
  • Displays KW, kWh & Run hour
  • Separate kWh and Runhour registers are provided for EB/DG
  • EB/DG selection displayed by LED
  • kWh range 9999999.9 kWh(LT), 99999999kWh(HT)
  • Runhour range 9999.59 hours
 
Optional Features
 
  • Accuracy class 0.5
  • Optically isolated RS485 Communication output with MODBUS RTU protocol
  • Separate energy register for export energy recording
   
Applications
   
  • Suitable for low cost applications
  • Captive Gen Sets
  • Individual machines & Equipments
  • Pumps, Motors & Compressors
  • Lighting Loads
   
Technical Specification  

 

PARAMETER SHOWN :

  • 1) Total kW
  • 2) R, Y, B kW
  • 3) kWh
  • 4) Run Hour

RATINGS :

  • Voltage Range : 80V to 520V AC line to line for LT
  • 25V to 140V AC line to line for HT
  • Standard Current : 1A / 5A
  • Max. Current : 1.5A / 7.5A
  • Frequency Range : 40.00 to 60.00 Hz
  • PF Range : 0.00 Lag to 0.00 Lead
  • Auxiliary Supply : 240V AC (-20% to +10%)
  • Operating Temperature: 55° C (Max.)

DISPLAY :

  • Type : 2 Row 16 Character LCD with Backlit
  • Character Size : 4.35 (H) x 2.95 (W) mm
  • LCD Power Save Mode : Provided. When no key is pressed for 3 minutes,the LCD Backlit is switched OFF to save power and enhance the life of LCD. The LCD is switched ON when any key is pressed

MEASUREMENT :

  • Method : 3 Phase 4 wire for LT 3 Phase 3 wire for HT
  • Accuracy : Class 0.5, 1

COMMUNICATION :

  • Type : RS485
  • Protocol : MODBUS - RTU
  • Isolation : Provided
  • Traffic Status : Indicated through TXD, RXD LED

OUTPUT :

  • Calibration LED : 3200 imp/ kWh

KEY FUNCTIONS

  • Key Pad : 4 Keys Index, Shift, Increment and Enter used for Program mode setting and Run mode selection
  • Program mode : PT Primary Voltage, CT Primary
  • Parameters : Current, Device address, Energy and Run hour Reset
  • Unauthorized Person Entry Protection: Provided through Password Facility
  • Setting, Energy and Run hour Storage in EERAM

  • CASE AND DIMENSIONS

    • Enclosure : ABS Plastic
    • Dimension : 96(H) x 96(W) x 80(D) mm
    • Cutout : 88(H) x 88(W) mm
    • Mounting : Flush / Panel

    • APPROVALS

    • Type test Approved as per IS14697 Standards for Class 1, Class 0.5 Confirms EMI, EMC Regulations as per IS14697 standards
     
     
    Untitled Document
    Home | About Us | Products | Quality Policy | Products Enquiry | Contact Us | Careers
    Infrastructure | Product Catalogues | Email
    .