MAXIMUM DEMAND CONTROLLER PCM9006
 
Features
 
  • Better Utilisation of available Power
  • Avoid Penalty, Disconnection
  • Improved Load Factor
  • True RMS measurement
  • Auto scaling from kVA to MVA
  • Predictive control method adopted to optimise demand control
  • Field programmable CT & PT ratios
  • Demand profile generation for setting realistic demand targets
  • Records 5 peak demands with date & time
  • Time of the day (TOD) facility
  • Integration time selectable : 15/30 minutes
  • RS485 communication interface to PC (optional)
  • 3 Control outputs for better control

 

  • ICD Maximum Demand Controller is applicable for medium and large scale industries to reduce demand peaks without affecting their operation. Maximum demand charges are collected based on the highest recorded demand peak in the month. By temporarily reducing or cycling the loads during the periods of high demand the maximum demand charges can be reduced.
    Two major benefits when maximum demand is limited to a predetermined level.
    1) Released electrical system capacity
    2) Reduced operating cost.

  • Controllable Loads
    1) Some electrical equipments load can be turned OFF for few minutes to hours without causing loss of production in convenience or harm. Heating process like storage water, slab, storage room, ventilation and air conditioner and battery charger are some of the loads that can be differed to reduce demand charges.

    2) Other restricted load to be carefully controlled are: Air compressor, Process Grinders, Refrigeration Motor, Electrical Furnaces, Pumps, Kilns etc.

    Maximum demand controller is a device designed to meet the need of load management for industries. Alarm is sounded when demand approaches a preset value. If corrective action is not taken, the controller switches OFF non essential loads in a sequence. The plant equipments selected for load management are stopped and restarted. Demand control is achieved by using suitable contactors and electrical hooters.

 

 

Applications
   
  • Main Incomers in Substations
  • Hospitals and Hotels
  • Process Control Industries
   
Technical Specification  
MEASURED QUANTITIES  
  • 1) 3 Phase, Phase to Neutral Voltage
  • 2) 3 Phase, Phase to Phase Voltage
  • 3) 3 Phase Current and Total kVA
  • 4) Rising demand and demand time
  • 5) Predictive demand
  • 6) Additional load capacity
  • 7)Time available to exceed the set point
  • 8) Maximum demand with date & time
  • 9) 24 hour demand with date & time
  • 10)Cumulative maximum demand
  • 11)MD reset count
  • 12)TOD demand and demand profile

    Ratings
  • Voltage Range : 80V to 520V AC line to line for LT
    25V to 140V AC line to line for HT
  • Standard Current : 1A / 5A
  • Max. Current : 1.5A / 7.5A
  • Frequency Range : 40.00 to 60.00 Hz
  • Auxiliary Supply : 240V AC (-20% to +10%)
  • Operating Temperature: 55° C (Max.)

  • Display
  • Type : 7 digit 0.5" high bright 7 segment Red colour LED Display
  • Character Size : 4.35 (H) x 2.95 (W) mm
  • LED Indication : Relay ON and Load Add/Remove

  • Key Functions
  • Key Pad : 8 Keys namely Index, Shift, Increment and Enter used for Program mode setting and Run mode selection
  • Program mode Parameters: PT Primary Voltage, CT Primary Current, Device address and Run hour MD Reset
  • Unauthorized Person Entry Protection: Provided through Password Facility
  • Setting, Energy and Run hour Storage in EERAM.

  • Measurement
  • Method : 3 Phase 4 wire for LT. 3 Phase 3 wire for HT
  • Accuracy : Class 0.5, 1

  • Output
  • Relay Output : 3 (1 for predictive demand and 2 for rising demand)
  • Contact Rating : 3A at 240V AC
  • Relay acknowledge : Provided

Communications

  • Type : RS485
  • Protocol : MODBUS - RTU
  • Isolation : Provided
  • Traffic Status : Indicated through TXD, RXD LED

  • Case And Dimensions
  • Enclosure : ABS Plastic
  • Dimension : 144(H) x 144(W) x 150(D) mm
  • Cutout : 136(H) x 136(W) mm
  • Mounting : Flush / Panel
 

       
PRAMETERS RANGE RESOLUTION ACCURACY
R, Y, B Voltage ( LT Meter) 180 V - 270 V 0.1 V + 0.5% + 2 least digit
RY, YB, BR Voltage (LT Meter) 310 V - 470 V 0.1 V + 0.5% + 2 least digit
R, Y, B Voltage (HT Meter) Primary Voltage 0.01 kV + 0.5% + 2 least digit
RY, YB, BR Voltage (HT Meter) Primary Voltage 0.01 kV + 0.5% + 2 least digit
Current 0 - 100 A 0.1 A + 0.5% + 2 least digit
kVA (LT Meter) 100 A & above 1:00 AM + 0.5% + 2 least digit
kVA (HT Meter) 0 - 1000 0.1 kVA + 0.5% + 2 least digit
Frequency 1000 & above 1 kVA + 0.2% + 2 least digit
RD kVA, PD kVA, MD kVA (LT Meter) 0 - 10000 1 kVA Better than + 1%
RD kVA, PD kVA, MD kVA (HT Meter) 10000 & above 0.01 MVA Better than + 1%
 