POWER FACTOR CONTROLLER PFC9055
Features
  • Measurement of PF for all the 4 quadrants
  • PF Indication between 0.00 lag to 0.00 lead
  • Control of PF from 0.80 lag to 0.95 lead
  • Suitable for switching IN/OUT capacitors through contractors
  • Control either in Auto or Manual
  • Optimum user of capacitor banks for increased life through cyclic switching
  • Adjustable connecting delay and reconnecting delay between the steps to suit the load changes
  • Selection of Capacitor Program
  • Entry of minimum Capacitor in kVAr
  • Alarm against over voltage, over current and over/under compensation
  • THD measurement and alarm(optional)
   
Applications
   
  • Power Factor Improvement in main incomers
  • Wind Turbine Generators
  • Hi-tech Software Parks, Buildings and Shopping Malls
  • Steel Rolling Mills and Process Industries
   
Technical Specification  
   
  • Type: ICD POWER FACTOR CONTROLLER
  • Model No. : PFC 9055
  • Voltage Input : 3 Phase 415V 50Hz for LT and 3 phase 110V 50Hz for HT
  • Burden : Less than 0.2 VA
  • Frequency : 40.00 to 60.00 Hz
  • Current Input : 1A / 5A from all the 3 Phase through current transformers
  • PF Measurement Range : For all 4 Quadrants
  • PF Measurement Accuracy: ±1% (+2 least digit)
  • PF Indicating Resolution : 0.01
  • PF Setting Range : 0.80 lag to 0.95 lead
  • PF Setting Accuracy : 0.01
  • Display : 7 Digit 0.5" seven segment Red LED
  • Parameter Displayed : Actual PF, Set PF, Actual kVAr and kVAr required to achieve set PF
  • Possible Program sequence Of capacitor banks: a) 1:1:1:1:1, b) 1:1:2:2:2 c) 1:2:2:2:2, d) 1:2:4:4:4, e) 1:2:4:8:8
  • Number of Steps : 4/6/8/12 in the form of output relays with NO contacts to operate the contactors
  • Output Relay : 3A at 240 VAC
  • NO contact Rating
  • Auxiliary Supply : Self Powered
  • Capacitor Connection : 5 to 240 Seconds adjustable Reconnection delay
  • Control Operation : a) Switching IN when the lag required kVAr value is more than 70% of the 1st capacitor value b) Switching OUT when the lead required kVAr value is more than 70% of the 1st capacitor value
  • Keypad for setting and selection: Index, Increment, Shift and Enter keys for setting PF, display and manual operation
  • Alarms with relay output : a) Over Voltage 115% of the rating b) Over Current 110% of the rating c) Over / Under compensation d) THD more than set point (optional)
  • Output Relay ON and manual: By LED indications
  • Operating Temperature : 55° C Enclosure
  • Dimensions : a) Bezel 144(H) x 144(W) mm b) Cut out 136(H) x 136(W)mm c) Depth 150 mm

 

 
 